smart line E
SLE 130 – 300
IMPORTANT!
DO NOT UNDER ANY CIRCUMSTANCES SWITCH ON THE
IMMERSION HEATER BEFORE THE PRIMARY TANK IS FILLED.
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - SLE 130 – 300

smart line E SLE 130 – 300 IMPORTANT! DO NOT UNDER ANY CIRCUMSTANCES SWITCH ON THE IMMERSION HEATER BEFORE THE PRIMARY TANK IS FILLED.

Page 2

TECHNICAL AND INSTALLATION 6Immersion Heater The SmartLineE range of tanks have the facility for fitting a 3kW immersion heater for back-up emergenc

Page 3

TECHNICAL AND INSTALLATION 74. COMMISSIONING Characteristics: Maximum water supply pressure to the reducing valve 16 Bar Operating pressure

Page 4

TECHNICAL AND INSTALLATION 85. MAINTENANCE ACV recommend that the cylinder is maintained by a competent person, this should be carried out every 12

Page 5 - INTRODUCTION

TECHNICAL AND INSTALLATION 96. TECHNICAL DATA Type SLE 130 SLE 160 SLE 210 SLE 240 SLE 300 Code 06604801 06604901 06605001 06605101 0660520

Page 6 - 1. OPERATION

TECHNICAL AND INSTALLATION 10 7. PERFORMANCE Performances Type Peak output (l/10min) 1st hour output (ltrs/60min) Continuous output (ltrs/hr) Boi

Page 7 - 2. CONSTRUCTION

TECHNICAL AND INSTALLATION 118. SYSTEM SCHEMATICS Typical un-vented application. Typical open vented application.

Page 8 - Domestic:

TECHNICAL AND INSTALLATION 12Typical ‘S-Plan’ schematic. ACV 6 PIN SOCKETFACTORY WIREDN IS SWITCHED LIVENOT NEUTRALCONTROL TERMINAL NUMBERING MAY DIF

Page 9 - Purging

TECHNICAL AND INSTALLATION 13Typical ‘Y-Plan’ schematic. ACV 6 PIN SOCKETFACTORY WIREDN IS SWITCHED LIVENOT NEUTRALCONTROL TERMINAL NUMBERING MAY DI

Page 10 - Immersion Heater

TECHNICAL AND INSTALLATION 149. DISCHARGE PIPE The discharge pipe (D2) from the tundish should terminate in a safe place where there is no risk to p

Page 11 - 4. COMMISSIONING

TECHNICAL AND INSTALLATION 15Extract from ‘The Building Regulations 1991 G3’

Page 13 - 6. TECHNICAL DATA

TECHNICAL AND INSTALLATION 1610. PARTS LIST Description Code 300mm Immersion Heater 11/2" BSP 3KW OI300 Thermostat pocket 438027 Manual air v

Page 14 - 7. PERFORMANCE

INDEX INTRODUCTION 1 Intended users of these instructions 1 Warnings 1 1. Operation 2 2. Construction 3 3. Installa

Page 16 - Typical ‘S-Plan’ schematic

TECHNICAL AND INSTALLATION 1 INTRODUCTION Intended users of these instructions: - The specifying engineer. - The installation engineer. - The owne

Page 17 - Typical ‘Y-Plan’ schematic

TECHNICAL AND INSTALLATION 2 1. OPERATION A = Stainless steel internal tankB = STW 22 carbon steel exterior tankC = High density polyurethane foam

Page 18 - 9. DISCHARGE PIPE

TECHNICAL AND INSTALLATION 3 2. CONSTRUCTION Internal tank: This tank is the heart of the assembly; it has to withstand the corrosive nature of

Page 19 - TECHNICAL AND INSTALLATION

TECHNICAL AND INSTALLATION 43. INSTALLATION (130 to 300 Smart Paks) Domestic: 1. Connect 22mm x 3/4" FI BSP adaptors to cold water inlet (blue

Page 20 - ORDER INFORMATION

TECHNICAL AND INSTALLATION 5Wiring the thermostat: To comply with ‘The Building Regulation 1991 G3.6’ the manual reset high limit thermostat must be